Condensate Contamination Detection System

Dumping contaminated condensate to waste automatically.

Condensate Contamination Detection System
 

Component Descriptions

Part Component Function
1 Controller to control the operation of the TDS control valve
2 Actuator to drive the control valve
3 Check Valve to provide enough resistance for flow through the sensor
4 TDS Control Valve to regulate the flow of the blowdown water
5 Isolating Valve to isolate the TDS control system from the blowdown line
6 Isolating Valve to isolate the TDS control system from the blowdown line
7 Conductivity Sensor to monitor the conductivity of the boiler water
8 Drain Valve to drain the sensor circuit for maintenance purposes
Arrow Top
 

Table of Parts

Part Component Spirax Sarco Reference Product details
1 Controller BC3200 TDS Blowdown Controls
2 Actuator EL5600 Series Electric Actuator Electric Actuators
3 Check Valve DCV1, DCV2 or DCV3 Wafer Check Valve Check Valves
4 TDS Control Valve QL33D, QL43D, QL63D, QL73D Three Port Valve Control Valves (See QLM & QLD Three Port Control Valves)
5, 6, 8, 9 Isolating Valve M10 Ball Valve Ball Valves
7 Conductivity Sensor S20 Sensor Chamber with CP10 Conductivity and TP20 Temperature Sensors TDS Blowdown Controls
Arrow Top