FTGS14C R SLR Sc

FTGS14C R SLR Sc
Arrow

FTGS14C L SLR Sc

FTGS14C L SLR Sc
Arrow

FTGS14C Z SLR Sc

FTGS14C Z SLR Sc

FTS14 R Base Sc

FTS14 R Base Sc
Arrow

FTS14 L Base Sc

FTS14 L Base Sc
Arrow

FTS14 V Base Sc

FTS14 V Base Sc

FTS14-C R SLR Sc

FTS14-C R SLR Sc
Arrow

FTS14-C L SLR Sc

FTS14-C L SLR Sc
Arrow

FTS14-C V SLR Sc

FTS14-C V SLR Sc

FTS14 R Base Fl

FTS14 R Base Fl
Arrow

FTS14 L Base Fl

FTS14 L Base Fl
Arrow

FTS14 V Base Fl

FTS14 V Base Fl

FTS14-C R SLR Fl

FTS14-C R SLR Fl
Arrow

FTS14-C L SLR Fl

FTS14-C L SLR Fl
Arrow

FTS14-C V SLR Fl

FTS14-C V SLR Fl

FT14 R Cover Sc

FT14 R Cover Sc
Arrow

FT14 L Cover Sc

FT14 L Cover Sc
Arrow

FT14 R Base Sc

FT14 R Base Sc
Arrow

FT14 L Base Sc

FT14 L Base Sc
Arrow

FT14 V Base Sc

FT14 V Base Sc

FT14 V Cover Sc

FT14 V Cover Sc

FT14 R Cover Fl

FT14 R Cover Fl
Arrow

FT14 L Cover Fl

FT14 L Cover Fl
Arrow

FT14 R Base Fl

FT14 R Base Fl
Arrow

FT14 L Base Fl

FT14 L Base Fl
Arrow

FT14 V Base Fl

FT14 V Base Fl

FT14HC R 1½-2"

FT14HC R 1½-2"
Arrow

FT14HC L 1½-2"

FT14HC L 1½-2"
Arrow

FT-15* ¾ / 1 / 1¼"

FT-15* ¾ / 1 / 1¼"

FT-15* ¾ / 1 / 1¼"

FT-15* ¾ / 1 / 1¼"

FT-15* ¾ / 1 / 1¼"

FT-15* ¾ / 1 / 1¼"

FTC32 Sc DN15-20 R

FTC32 Sc DN15-20 R
Arrow

FTC32 Sc DN15-20 L

FTC32 Sc DN15-20 L
Arrow

FTC32 Fl DN15-20 R

FTC32 Fl DN15-20 R
Arrow

FTC32 Fl DN15-20 L

FTC32 Fl DN15-20 L
Arrow

FTC32 Sc DN25 R

FTC32 Sc DN25 R
Arrow

FTC32 Sc DN25 L

FTC32 Sc DN25 L
Arrow

FTC32 Fl DN25 R

FTC32 Fl DN25 R
Arrow

FTC32 Fl DN25 L

FTC32 Fl DN25 L
Arrow

FT43 L < 1" SLR

FT43 L < 1" SLR
Arrow

FT43 V < 1" SLR

FT43 V < 1" SLR

FT43 V Side < 1"

FT43 V Side < 1"

FT43 L = 1" SLR

FT43 L = 1" SLR
Arrow

FT43 V = 1" SLR

FT43 V = 1" SLR

FT43 L > 1" SLR

FT43 L > 1" SLR
Arrow

FT43 V > 1" SLR

FT43 V > 1" SLR

FT44/6/7 R = 1"

FT44/6/7 R = 1"
Arrow

FT44/6/7 L = 1"

FT44/6/7 L = 1"
Arrow

FT44/6/7 V = 1"

FT44/6/7 V = 1"

FT44/6/7 L = 1" SLR

FT44/6/7 L = 1" SLR
Arrow

FT44/6/7 V = 1" SLR

FT44/6/7 V = 1" SLR

FT44/6/7 R > 1"

FT44/6/7 R > 1"
Arrow

FT44/6/7 L > 1"

FT44/6/7 L > 1"
Arrow

FT44/6/7 V > 1"

FT44/6/7 V > 1"

FT44/6/7 L > 1" SLR

FT44/6/7 L > 1" SLR
Arrow

FT44/6/7 V > 1" SLR

FT44/6/7 V > 1" SLR

FT450 R Sc ¾"

FT450 R Sc ¾"
Arrow

FT450 L Sc ¾"

FT450 L Sc ¾"
Arrow

FT450 R Fl ¾"

FT450 R Fl ¾"
Arrow

FT450 L Fl ¾"

FT450 L Fl ¾"
Arrow

FT450 R Sc 1½"

FT450 R Sc 1½"
Arrow

FT450 L Sc 1½"

FT450 L Sc 1½"
Arrow

FT450 R Fl 1½"

FT450 R Fl 1½"
Arrow

FT450 L Fl 1½"

FT450 L Fl 1½"
Arrow

FT450 R Sc 3 / 4"

FT450 R Sc 3 / 4"
Arrow

FT450 L Sc 3 / 4"

FT450 L Sc 3 / 4"
Arrow

FT450 R Fl 3 / 4"

FT450 R Fl 3 / 4"
Arrow

FT450 L Fl 3 / 4"

FT450 L Fl 3 / 4"
Arrow

FT450 R 2Fl 3 / 4"

FT450 R 2Fl 3 / 4"
Arrow

FT450 L 2Fl 3 / 4"

FT450 L 2Fl 3 / 4"
Arrow

FT-150* ¾ / 1"

FT-150* ¾ / 1"

FT-150* ¾ / 1"

FT-150* ¾ / 1"

FT-150* ¾ / 1"

FT-150* ¾ / 1"

FT-150* 1¼ / 1½"

FT-150* 1¼ / 1½"

FT-150* 1¼ / 1½"

FT-150* 1¼ / 1½"

FT-150* 1¼ / 1½"

FT-150* 1¼ / 1½"

Naming Conventions for Product Drawings

The basic naming convention generally consists of the product name followed by its view or orientation. For example, TD42 L is a TD42 Thermodynamic steam trap shown with flow from left to right.

Abbreviation Example Meaning

product views & orientations

R TD42 R Right to left flow
L TD42 L Left to right flow
V or Ver FT14 V Cover Sc Vertical flow
Z FT14 Z Sc Z axis view (for example, the view looking through the centre orifice)
Fi ILVA Fi L Full image

connection types

Sc BPT21 L Sc Screwed
Fl BPT21 L Fl Flanged
Wd BTD52 L Wd Weld
Bw AV45 Bw L Butt weld

product options

B/down or Bd TD42 L Bd+Iso Blowdown version
Iso or Isotub TD42 L Bd+Iso Isotub option (for Thermodynamic steam traps)
H or Hor FT54H* L Horizontal version
V or Ver FT54V* Vertical version
SLR FT14 L SLR Sc Steam lock release option

other conventions

* BSA1* L More than one product shares this drawing (for example, the BSA2 & BSA3 look the same as the BSA1 so use the same drawing)
# BC 3200# Insert the drawing using a scale factor of 1:1